Mac valves inc ann arbor road dundee mi

in Dundee, MI. Discover more Industrial Supplies companies in Dundee on fikohywe.cf ANN ARBOR Road Dundee, MI Mac Valves is a privately held company in Dundee, MI. Categorized Detroit Nipple Works Inc. Detroit, MI .
Table of contents



If you have an application that would benefit from utilizing the axial flow cartridge option or wish to discuss other potential cartridge modifications, please consult your local MAC distributor MDN Associate. By understanding your application and valve requirements we can optimize the valve settings accordingly. Improper use, installation or servicing of any MAC Valves product in some systems could create a hazard to personnel or equipment. No distinction in importance should be made between the terms warnings and precautions.

Under no circumstances are MAC Valves products to be used in any application or in any manner where failure of the MAC Valves product to operate as intended could in any way jeopardize the safety of the operator or any other person or property. Never attempt to repair or perform other maintenance with air pressure to the valve.

These products are not inherently dangerous, but they are only a component of an overall system. The system in which they are used must provide adequate safeguards to prevent injury or damage in the event failure occurs, whether it be failure of switches, regulators, cylinders, valves or any other component.

Therefore, if pressurized air retained in the system would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the trapped air. Listed below are the various center position functions: If trapping the air in both outlet ports would present a hazard in the application or servicing, a separate method in the system must be provided to remove the trapped air or this type valve should not be used.

If having pressurized air to either or both outlet ports would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the retained air or this type valve should not be used. This series provides On all models.

On solenaid models. The remote air versions feature: The Series is a small Inline 4-way valve with a Cv of up to 1. A OPER. Requires sandwich regulator. Main exhaust cannot be restricted. ISO 2. TM pilot body is replaced by TU pilot body. Available only on single pressure valves. Epoxy encapsulated. Single operator and 3 positions: Voltage range: Continuous duty.

For light in body replace A by C. ISO 1. For light replace A by F. TU replaces TM. Use TU pilot body for pilot exhaust to main exhaust. For piped pilot exhaust replace TM by TP. Light Main exhaust cannot be restricted No flow controls available with single pressure valve only. Replace K by L for bottom cyl. B IN Ext. Pilot signal can be from 20 to PSIG. For dual pressure valves see page for use with sandwich regulators. Example D To order bases without the valve. The valve less base is always the same for internal or external pilot. ISO 1 Note: Above codes shown are for side ports.

For piped pilot exhaust replace M by P. These options are effected in the base. PILOT For dual pressure valves with lights on valve body see page for use with sandwich regulators. ISO 2 Note: For lights on valve body. ISO 3 2. For side ports with lights on base.

Above codes shown are for side ports without lights. To order manifolds without the valve. When ordering an external pilot connection for manifold bases. ISO 2 3. Above codes shown are for side cylinder ports. One connection only is required for all the valves in the manifold whether single or double solenoid. Manifolds for solenoid and remote air operated valves must be ganged separately.

Mac Valves Cataloge

For bottom and side cylinder ports. ISO 3 4. MOD Bottom inlet port in addition to side inlet port. For bottom cylinder ports.


  • bahama breeze mac and cheese.
  • Contact Us | Mac Valves;
  • Valves & Pipe Fittings Manufacturers : - A2ZYP - Yellow Pages - Record Start From .
  • Dundee, MI Business Directory - Page 2 | US Business.
  • reset mac os x password with cd?
  • Existing Subscriber Sign In?
  • force empty trash mac program.

These options are effected in the manifold. ISO 3 3. Above codes shown are for side cylinder ports without lights.

Documents Similar To Mac Valves Cataloge

For side cylinder ports with light. One connection only is required for all the MAC A valves in the manifold whether single or double solenoid. B IN 45 Ext. A EXH. Open Center or Pressure Center solenoid or remote air. For dual pressure valve.

Are You ...

Bottom ports: Refer to modification table. ISO 2 Bottom inlet. Example B Continuous duty Voltage range: For lights on base. These options are MOD.

CYL A For lights on manifold. MAC A Sgl. A IN 45 Ext. These options are effected in MOD. Add the appropriate modification number after the valve number. Example A Bottom inlet. Dimensions shown are metric mm dimensions DBL For dual pressure valve replace by 4 no light. MAC A 5. One connection only is required for all the valves in the MAC A side cyl.

Catalog - Mac Valves | fikohywe.cf

Available in external or internal pilot supply models. The combination spring and air assist assures fast. The accumulator is then supplied through the external supply connection. Supplied from the accumulator it balances the shifting forces for consistent operation and positive spool return. The access cover also houses the optional indicator lights.

They are provided with an integral electricial wiring space. All spool seals are permanently bonded. For external pilot poppet. Internally piloted. These valves with their pressure balanced design are or piped exhaust. The check valve is designed to biased MAC Series three-way manifold valve which features a high flow balanced bleed off the accumulator when the main supply pressure is removed.

Direct solenoid and solenoid pilot operated valves Series Individual mounting Series inline Manifold mounting 35 stacking body stacking body stacking body stacking body stacking body with 3 common with 3 common with 3 common with 3 common with 1 common ports ports and ports with ports with C. When two pressures are required within a valve. For the following special applications. The External Pilot supply is connected to the External Pilot ports connected to the vacuum supply and port 1 Inlet to atmosphere. If more than two pressures are required.

JD Norman Industries Testimonial of MAC Valves Pulse Valve on Dust Collector (EN Subtitles Only)

PSIG on 3-position double solenoid models. The valve is the same valve for either Internal or External Pilot. If both pressures are below the minimum. By isolating. In either case. Additionally the following must be adhered to: The For dual pressure. The valve must be an External Pilot model. For single pressure. For 2 position dual pressure: With fast response times, reliable shifting forces and repeatable results — due to its patented balanced design — the MAC LBV is ideal for applications that demand reliable, low-leak performance.

With fewer wear points than traditional valve technology the LBV is designed to last. They are generally used to operate spring return cylinders or as pilots for larger diaphragm or piston operated valves Small 3 Way Valves Air flows up to 1. Their common application is to operate double acting cylinders. Small 4 Way Valves Air flows up to 1. MAC Pulse Valves are ideal to replace existing diaphragm technology in applications such as reverse jet bag houses and dust collectors, pneumatic conveying and bulk material handling.